# What a spreadsheet rewrite actually costs

> 108 published workbooks, 464,872 formula cells: 99.1% translate mechanically. The cost is the 58.7% of columns computed two ways.

Source: https://plantroomlabs.com/notes/what-a-spreadsheet-rewrite-actually-costs/  
Published: 2026-10-14 (14 October 2026) · Plantroom Labs  
Topics: Spreadsheets, Web apps, Measurement

A rewrite is quoted on how many formulas there are. Across 464,872 of them, 99.1% translate mechanically &mdash; and the price is set by the ones that do not.

## The part everybody worries about is the cheap part

Ask what it costs to turn a spreadsheet into a web application and the conversation goes to the formulas: how many there are, how gnarly they look, whether anyone still understands the nested one in column H. That is the wrong thing to count, and this note is the measurement that says so.

108 spreadsheets published by UK government, holding 464,872 formula cells between them. Of those cells, **99.1%** use functions with a direct equivalent in any web stack you would pick — sums, lookups, dates, text handling, conditionals. Translating them is typing. What costs money is the 0.5% with no faithful translation at all, and the 58.7% of filled columns where the same calculation is done more than one way down the column.

## What was measured, and what was not

The corpus is 123 spreadsheet URLs published on GOV.UK's asset host, collected one at a time with a named user agent, after reading that host's `robots.txt` — and after being refused the data.gov.uk catalogue API, which disallows the path its own search redirects into. Deduplicated by content hash that is 108 distinct workbooks plus five duplicate copies, which are reported rather than dropped, because a file published twice under two names is a fact about how these sheets circulate. Another ten files could not be read at all.

The instrument reads formulas. It does not *evaluate* them: no cell was computed, so there is no claim anywhere below about a spreadsheet getting a wrong answer. Every figure here is about the shape of the logic, which is the thing a rewrite has to reproduce.

> **The first finding is that most of them are not programs.** 77 of the 108 workbooks — 71.3% — contain no formula at all. They are tables. A table is an import, not a rewrite, and it is worth establishing which one you have before quoting either.

## A formula count is not a rule count

The 31 workbooks that do hold logic hold 464,872 formula cells — and **10,287 distinct rules**. A formula filled down a column is one rule the moment you normalise its relative references: every cell in it says "the cell three to my left times the cell above me", and a rewrite implements that once. Collapsing identical shapes that way, 464,872 cells come to 10,287 rules, a ratio of 45.2 to one.

The average hides the interesting part. The median workbook is only 11.2 cells per rule; the most repetitive is 1,028.4. The largest sheet in the corpus, `Materials_Facility_Combined_Waste_Returns_Spreadsheet.xlsx`, holds 96,668 formula cells and **94 rules**. A quote priced on its cell count would be wrong by three orders of magnitude.

## Two ways this measurement was wrong first

Normalising a reference is where the bugs live, and both of the ones here pushed the answer the same way — towards making spreadsheets look harder than they are.

The first: a reference carrying a sheet name was not normalised. A formula reading `Other!B2` alongside a local `B2` had one half turned into an offset and the other left as a literal address, so the same formula filled down a thousand rows produced a thousand different shapes — a thousand rules where there is one. The second: a workbook can store a formula once and have the rest of the column point at it by index, carrying no text of their own. Those followers were being skipped, so a column filled down thousands of rows counted as a single cell. One error inflated the rule count and the other deflated the cell count, and together they made the cells-to-rules ratio meaningless.

Both are fixed, both figures above are post-fix, and the general lesson is the one worth taking: a reference normaliser has to handle the qualified form and the shared form, or it is measuring its own regex.

## The 0.5% that has no translation

Of 464,872 cells, 460,904 are mechanical. 1,611 — 0.3% — use a function the instrument does not recognise, which means somebody has to read them rather than that they are hard. The 2,357 that are genuinely unrepresentable — 0.5% — break down into four kinds, and each one is a conversation with the client rather than a line of code:

- **1,354 volatile cells.** `TODAY()`, `NOW()`, `RAND()`. In a sheet these change when the file is opened; in a web application the same page has to decide whether the figure is recomputed on every view, frozen at submission, or stamped once a day. Three different answers, three different products.
- **743 cells saved holding an error**, in 19 of the 31 workbooks. `#N/A`, `#DIV/0!`, `#REF!` — published that way. A rewrite cannot reproduce an error faithfully, so each one is a question: is this cell expected to be blank, or has the sheet been broken since before the last person left?
- **259 approximate lookups.** A `VLOOKUP` with its last argument left off or set true does not find a match, it finds the nearest row below — on data that has to be sorted for that to mean anything. Ported to an exact-match query it returns different answers, and ported faithfully it inherits a sorting requirement nobody wrote down.
- **one computed reference.** Exactly one cell in the corpus builds an address and then reads it, via `INDIRECT` or `OFFSET`. These are the formulas people expect to be the problem; they are one cell in 464,872.
No formula in the corpus reads a cell in another workbook. At the file level 21 of them carry a link to one anyway — a connection saved into the file, pointing somewhere on a drive that may not exist now.

## Where the cost actually is

Across the 22 workbooks with a filled column at all, there are 972 such columns and 1,261 runs of a repeated rule inside them. **571 of those columns — 58.7% — compute their values more than one way**, with 1,578 extra shapes between them, across 18 workbooks.

That is not by itself a defect. A total row at the bottom of a filled column is a second shape and a correct one; two stacked tables sharing a column are two rules, not a rule with exceptions. But every one of them is a decision somebody has to make during a rewrite, and the person who can make it is the person who knows what the sheet meant — not the developer reading it. That is the line item a formula count cannot see, and it is why the estimate that matters is hours of somebody's attention, not lines of logic.

Looked at by eye the variants are exactly what you would guess. In one workbook a column of lookups wraps each in `IFERROR`, except for the cell that doesn't; two cells further down gained a wrapper the run above them lacks. Harmless, until the rewrite has to pick one behaviour for the column and somebody notices the blanks moved.

## What an exception is, and two wrong ways to define one

The figure above went through three definitions before it was honest, and the first two both overstated the case badly enough to have been worth publishing as a warning.

Version one took the most common shape in a column as the rule and called every other cell a mistake against it. On that definition most columns in the corpus carried disagreement — but a summary column holding a stack of unrelated one-off formulas has no rule at all, and whichever two of them happened to match became the rule while the rest became defects. Version two required the dominant shape to hold a real majority of a real number of cells. Better, and still mostly wrong, for the same reason: a column with one table's subtractions above another table's lookups is two rules, not one rule with twenty exceptions.

The definition that survived is about runs rather than totals. A rule is a run of consecutive cells with the same shape, long enough not to be a corner of a table. An *exception* is a short run sitting between two long runs of the same shape — so the rule demonstrably resumes after it, and the interruption cannot be explained as the column simply moving on to something else. By that definition there is one exception in 972 columns: 0.1%, in one workbook, `HARC_DRC_programme_Improving_food_security_nutrition_protection_Budget_template_Annex_3.xlsx`.

> **The pattern is the point.** Each looser definition of "broken" produced a scarier number, and each scarier number was an artefact of the definition. A measurement that makes your sales pitch for you is the one to re-derive before publishing.

## What a rewrite finds that nobody mentions

The same pass counts the things that do not appear in any brief:

- **15 of 31 workbooks (48.4%) leave a sheet with formulas on it unprotected** — so any user can overwrite the calculation with a number, and the file gives no sign afterwards. This is the single best argument for the rewrite, and it is never the one on the list.
- **2,187 distinct hard-coded numbers** sit inside 112,535 formula cells — rates, thresholds, unit conversions, written into the logic instead of into a cell with a label. Each is a value somebody will need to change, and a rewrite either lifts it into configuration or buries it again.
- **25,617 constants are read by a formula, against 4,330,020 that are not.** The second number is the scale of what a migration can usually leave behind, and the first is the one that has to appear in a form.
- **27 workbooks hide a sheet.** Hidden is not secret — it is usually a lookup table, and it is usually where the rates live.

## The extension lies, sometimes

All ten unreadable files are legacy binary workbooks, the pre-2007 format, which this instrument declines to parse rather than guess at. The part worth knowing is that **two of them are published with a modern `.xlsx` name**: `Lighting_Tool_190314.xlsx` and `Model_Tester_130314.xlsx`, both beginning `d0cf11e0` — an OLE compound file, not a zip.

Anything in a migration that routes on the extension will take those two down the wrong path, and the error will look like a corrupt file rather than a mislabelled one. Read the first eight bytes; the name is a claim, not a measurement. The container of every file in this corpus is recorded that way, which is why the figure above can be checked without the files.

## What this does not tell you

Four limits, and the third is the one that would change the headline:

- Nothing was evaluated. No formula was computed and no result was compared to anything, so there is no claim here about any of these sheets being wrong.
- The legacy binary files were not parsed. Whatever logic is in those ten workbooks is absent from every figure above.
- **This is a government publication corpus, not a business one.** It skews heavily to blank templates, reporting returns and open data — which is most of why 71.3% hold no logic. It under-represents the thing a rewrite is usually commissioned to replace: one fifteen-year-old operational workbook that runs a department, where the ratios would look nothing like these.
- Prevalence is counted per published URL and deduplicated by content, so a workbook that circulates widely counts once. That is the right call for "how are spreadsheets built" and the wrong one for "what do people open most".

## Doing this to your own sheet

In the order the answers change the price:

- Count rules, not cells. Normalise the relative references and collapse the duplicates — including the qualified references and the shared-formula followers, or the count will be wrong in both directions at once.
- Find the columns computed more than one way. Each is a decision for whoever owns the sheet, and together they are the schedule.
- List the cells with no faithful translation — volatile, cached error, approximate lookup, computed reference — and get a ruling on each before quoting, because each is a product decision wearing a formula's clothes.
- Check for an unprotected formula sheet, and for hard-coded rates inside formulas. That is the pair that usually justifies the work.
- Check the first bytes of every file against its extension before anything routes on the name.
The instrument behind this note reads formulas and reports shapes; the figures above are re-derived from its output on every build of this site, so a number in the prose that drifts from the measurement fails the build rather than ageing quietly. That is the same discipline we bring to [replacing a spreadsheet with something auditable](https://plantroomlabs.com/services/spreadsheet-to-web-app/) and to [a pipeline that gates its own claims](https://plantroomlabs.com/services/web-and-devops/).
